Is it possible to install timber columns as a load-bearing structure in high-rise buildings in terms of fire protection? This question was determined as part of the loaded fire resistance test on a hinged glulam column (structural beech column). The fire resistance test was carried out in accordance with DIN EN 1365-4:1999-10 in conjunction with DIN EN 1363-1:2020-05 under a four-sided thermal load using the unit temperature-time curve (ETK). The aim of the test was to determine the load-bearing capacity in accordance with DIN EN 1363-1:2020-05 and the fire resistance duration of at least 120 minutes using the test set-up regulated in accordance with DIN EN 1365-4:1999-10. Following the fire test, the residual load-bearing capacity of the column was tested up to the load-bearing capacity failure.

More projects

Brandversuche zur Löschwirkung einer Feuerlöschanlage mit einem maßstabsgetreuen Nachbau eines Raumes in einer alten Industriehalle

Fire testing regarding the performance of a fire-extinguishing system

To test the extinguishing effect of a sprinkler system of the company Minimax GmbH & Co. KG in an…

Read More

Kombination eines Fotos zum Brandversuch mit Montagesystemen und einem FEM Modell

Mounting systems according to EAD 280016-00-0602

Characterization of the performance properties under ambient temperature and in case of fire

Read More

Gerät ( Torrent) zur Messung der Permeabilität von Beton an einer Betonstütze gehalten von einem Mann mit Bauhelm und Warnweste

Non-destructive measurement of permeability of concrete

Non-destructive measurement of permeability for the evaluation of concrete properties with respect…

Read More