To verify impact resistance of the new glass façade of the Leipzig Gewandhaus as part of its testing activities, MFPA Leipzig GmbH carried out a pendulum impact test according to DIN 18008-4:2013-07 in April 2021.

The goal was to verify protection against a collapse of the glazing, by administering multiple pendulum blows to different parts of the glass façade. In line with the specifications, a pendulum body with the following characteristics was used: Dual tyres with a mass of 50 kg, an internal pressure of 3.5 bar and a deflection height of 90 cm.

More projects

Lärmschutzwandanlagen reduzieren die Lärmbelastung an Bahnstrecken

Laminated safety glass noise protection wall elements along railway tracks

The aim is to develop concrete proposals for providing proof of usability for the transparent…

Read More

Stress corrosion examination on bridge structures

In order to assess the current condition of the structure, prestressing steel, grout and parts of…

Read More

Lärmschutzwand in horizontaler Lage während einer Dauerbelastungsprüfung

Dynamic bending test of a noise protection wall

In order to obtain an approval by the Federal Railway Authority, the business unit Supporting…